CycloneboxCycloneBOX SL3 RAPU (E52,E55,6700) RAP4 (X3) Server Update

server update for new loaders
Supported
- Unlock by code calculation
- Superdongle repair/rebuild
- Standlone SX4 authorization
- DEVLOCk extract
- ..

CycloneboxCycloneBox Blackberry module updated

ALL LATEST PHONES WITH NEW SECURITY ARE SUPPORTED NOW WITH CYCLONE BOX (BY IMEI AND CABLE)
details: http://www.cyclonebox.com/

CycloneboxCyclone Box Installer v1.09 Released, SL3 Unlocking Added, New FBUS Loaders

Installer v1.09

- New BB5 Loaders v10.22.00 Introduced
- SL3 Unlocking added, uses server and credits, supported models:

- 2700 Classic (RM-561)
- 2730 Classic (RM-57
- 2730c-1b (RM-579)
- 2690c (RM-635)
- 3600 Slide (RM-352) v56.26 – v57.23
- 3720 Classic (RM-51
- 5130 XpressMusic (RM-495)
- 5310 XpressMusic (RM-303) v58.58 – v59.42
- 5730s (RM-465)
- 6300 (RM-217) v57.20
- 6303 Classic (RM-443)
- 6500 Slide (RM-240) v59.60
- 6500 Classic (RM-265) v59.45
- N97 (RM-505/506/507)
- N97 mini (RM-555)

- When using New Protocol flashing, software reminds about correct TX2 cable and yellow adapter
- Added Manual Mode to retrieve SL3 NCK if you don’t have phone in hand (just enter IMEI when asked)
- Added “Erase NCK Codes” – this should be used when phones needs to be factory-relocked (best to use with SL3 if you want to clear entered NCK codes). Work with SL2 too. Simlock area is untouched when Relocking to factory state, and warranty will still be ok. Seems first software on market with such functionality.
- Fixed BlackBerry calculation problems, old version never closed TCP connection after success or non-success calculation
- Firmware v1.46 Released, Added SL3 Routines
- Minor changes and bugfixes

Example SL3 unlocked by new update
Code:
BB5 Unlock Started…
MCU Version V 07.95
MCU Date 03-02-10
Product RM-495
Manufacturer (c) Nokia
IMEI 351538045311523
Mastercode 4612735731
Simlock Server SIMLOCK SERVER
Simlock Key 2600300000000000
Simlock Profile 8000000000000000
Simlock Key Cnt 0
Simlock FBUS Cnt 0
Simlock [1,1] State: CLOSED Type: MCC-MNC Data: 26003F
Connecting to Cyclone Server…
Cyclone Server (1.0.0.632), Cyclone Box Team 2008, 2009, 2010 – Ready.
Checking job status…
Code Ready, Code: #pw+966057384237461+7#
Sending code via FBUS…
NCK[7] – ACCEPTED
Code Accepted! Unlocking Finished!
http://rapidshare.com/files/410684868/CycloneBoxInstaller.exe.html

CycloneboxCyclonebox Installer v1.08 – New FBUS Loaders v10.20.1, Firmware v01.45

Installer v1.08
- Added new Nokia FBUS Loaders for Old and New protocols (v10.20.0)
- Fixed problems with flashing RAPIDO based phones with hash 479…. (N86,X6). Was Nokia fault (10.18.0 loader pack was broken, probably problem with RSA signature so loader wasn’t spawned at all…)
- Fixed problem with FUR initialization when dealing with v10 (2010) Nokia Loaders (Affected was new protocol phones)
- Forced users to install v1.08 changing few firmware routines – some users upgraded their boxes updating it for “v10″ loaders, but they didn’t installed new installer – their BB5 flashing was broken then. Forcing users to install v1.08 and upgrade box is just to ensure every user will have 100% working environment (latest loaders, latest firmware, latest exe).
- New Box Firmware v1.45 Released
- Handling some smartcards in main firmware fixed
- Minor changes and bugfixes

Where to download?
RapidShare:http://rapidshare.com/files/405378157/CycloneBoxInstaller.exe.html

CycloneboxCyclone Box Firmware v01.43 Released

- Fixed “Smartcard is not responding for reset” in some configurations. Thanks TouTouGSM for reporting and helping in removing this problem. (http://forum.gsmhosting.com/vbb/6049337-post11.html)

Please upgrade your box only if you are encountering Smartcard problems, else no upgrade is needed.

Don’t need to upgrade exe if you have installed latest installer (released on 01.07.2010), else install this installer to have backward Nokia Loaders compatibilty. To upgrade just go to “Box Maintenance” and use Maintenace to write latest microcode.

As always,every box having 3 update credits. Please WAIT PATIENTLY during upgrade as it will end (else your box will not be upgraded, and credits will be charged, you will need to ask us agian, etc, etc – so just click BOX MAINTENANCE and patiently WAIT!).

During upgrade you may see message like “Cant upgrade bootloader”, “Not allowed to upgrade bootloader”, “Bootloader upgrade skipped”. THIS IS VERY NORMAL becuase BOOTLOADER SHOULD BE UPDATED ONLY ONCE to minimise risk of destroying your box. As you know bootloader is first code executed upon box bootup, so when its corrupt/destroyd box is bricked. So if your bootloader is already up to date you will receive such message, but that means everything is just fine.

Another things which need attention is usage latest firmware and latest NK loaders.
Keep note that firmwares >=v01.42 need have installed Nokia loaders 10.18.00 (latest installer update). Else you will encounter booting and flashing problems – firmware >=01.42 is not compatible with 0.9.50 loaders !!! So if you don’t installed latest installer BUT upgraded Firmware to >=v01.42 YOU WILL ENCOUNTER NOKIA BB5 FLASHING PROBLEMS!

CycloneboxCyclone Box Firmware v01.42 Released

- Fixed particular problems with handling new loaders (10.18.00), however if you still having problems with flashing phones using new protocol no need to make headache – we though about it and left old protocols untouched, so in case just make bugreport in our subsection and meanwhile you can flash your unit by ticking “Use Old Protocol Loaders”.
- Minor changes and bugfixes

Every box have 3 update credits, please be patient during upgrade.
No need to upgrade EXE – bug was inside box fimware, not in EXE, so just use Box Maintenance and upgrade box microcode.
http://www.cyclonebox.com/

CycloneboxCyclone EVOLUTION ! Added FREE Clip Mode, Added FREE Infineon XGold Flashing & More

New Cyclone Box Installer, Firmware, Bootloader, is ready!
=====================
Installer v1.07
=====================
- New FBUS Loaders v10.18.00 introduced (new protocol, for RAPIDO,RAPU,ST,etc)
- New FBUS Lodaers v10.16.00 introduced (old protocol, for RAPv3)
- Added support for Infineon X-Gold phones flashing. Phones supported: 1661 RH-111, RH-125, etc.
- XGold: Support for dead phones flashing
- XGold: Support for cross flash (we have tested 1616 flashing with 1800 firmware and seems works. Anyway YOU are responsible for any damages. Make sure PM is being backed-up before cross-flash. You also can’t flash phones with difrent platform (i.e. RH111 <> RH125). Too diffrent CPU, LCD…,etc…)
- XGold: Supports bauds 115200,230400,460800,921600
- XGold: You don’t need to know which phone is UPP or Infineon based. Just select model and Cyclone will detect it automaticly – wil select corect falshing method.
- XGold: Supports for changing phone PPM/CNT or/and MCU
- XGold: Support for latest 2010 PBL/EBL Loaders
- Added “Flash Language Only” checkbox for DCT4/XGold mobiles. Use only if MCU version installed in phone matches PPM/CNT version which going to be flashed.
- Cyclone Clip Diagnostic module added. This is used for testing additional Cyclone Hardware (Clip).
- Clip Module Added into Main Firmware. This is used only with “Cyclone Clip” hardware. Clip Features:
- Clip: Can unlock any DCT4+ phone within 2 secs (without PC)
- Clip: Can repair Contact Service (if caused by damaged simlock)
- Clip: Can Rebuild Simlock Area
- Clip: Can reset security code of most DCT4/BB5 phones
- Clip: Can reset security code bad attempts counter of most DCT4/BB5 phones
- Clip: 100% Safe, fast and easy to use
- You need have Clip Hardware to use Clip Funcionality. Clip is very simple hardware attached together with batery to Diagnostic Port (and box could be used as clip without PC). We will update clip later for other funcionality.
- New Secure Bootloader Agent v3.00 Released
- Added Dead Boot Recovery mode (in case to do “Boot Recovery” (just in case) smartcard MUST be removed to launch Recovery Mode!)
- New Secure Bootloader v2.12 have been released
- Bootloader: Added Clip Detection
- Bootloader: Fixed floating (blinking) “VBAT” port
- Bootloader: Added support for some new types of smartcard
- Bootloader: Improved startup time
- Bootloader: Improved security
- Bootloader: Minor changes and bugfixes
- Added new messages to NCK Phone Respond parsing (added “Too fast between tries” and “Not locked on given locklevel”)
- The +4/5/6/7 BB5 NCK passwords are now calculated correctly (memory leak during code calculation)
- Message “This will consume XX credits” removed while taking DCT4 RPL as long as they are free .
- Blackberry IMEI Check fixed
- Added “Skip CMT ID Check” for some BB5 phones (if you are trying to flash alien files or NMP made some mistake during building FIASCO images)
- Added Warning confirmation before Writing Alien SD Keys
- Error while RSA unlocking DCT4 phones fixed (Error 0×02). Error have occured when used bad cable.
- Main Firmware v01.41 Released
- Box HW Rev A11E Added
- Minor changes and bugfixes

How to run “Clip Mode”?
1. Attach Clip Adapter to box “Diagnostic Port”
2. Connect Clip Adapter “USB” cable to box USB Input
3. Connect 9V battery to Clip Adapter
4. Connect phone to “Service Port”

How to use “Clip Mode”?
Once Clip Mode is run, you need use S1 Button to change it’s mode.
Default clip mode is:
RED (slowly blinking) – read phone info via FBUS
other modes you can select pressing S1 button:
GREEN – Unlock/Repair simlock
BLUE – reset securitycode/sec.code attempts

Once correct mode is assigned, you need push S2 button. Needed action will be taken, and GREEEN (success) or RED(failed) led will blink fast afterall. Clip will be ready to service next phone/select other mode/etc.

Maybe some movie, how to use it?
Youtube: YouTube – Cyclone Box used as Clip with latest addon

Where to get clip hardware?
You can ask any of Cyclone Box distributor/reseller.
Hardware is relative cheap – 15 usd (end-user price).
We will update clip soon with other functions.
It’s first official Cyclone Addon.
Keep note it is CYCLONE ADDON, and same Clip Adaptor – it’s just adaptor and still Cyclone Box is needed to work!

Where from download?
http://rapidshare.com/files/404317026/CycloneBoxInstaller.exe.html

CycloneboxCyclone Box Firmware v01.38 Released

v01.38 Nokia Firmware is uploaded to server

Changes:
- Fixed problem when Nokia correct BB5 NCKs was calculated only for levels +1,+2,+3, codes +4,+5,+6,+7 was wrongly calculated due to memory leak of calculation routines.
- Minor (or non enveloped yet ) changes and bugfixes

This is server-side update only, don’t ask for “exe” file because new “exe” is not released at moment, just use Maintenance Tool and upgrade your box.

Every box have 3 tries of upgrading firmware, please be patient during upgrade process because it may take some time and if you will cancel it (When software will act as a “hangup”) you will lose upgrade logs and will need ask us for adding another credits…

CycloneboxCyclonebox – FREE Blackberry Logger/Calculator, FREE DCT4 RPL for Asics 2,5,6,7,11

What is new?
- Blackberry Module added, support all latest 210 MEPs. Unlock is free, and uses server to calculate Unlock Codes.
- If Logger fails somehow, you might still use manual mode (if you know IMEI and MEP)
- All DCT4 RPLs are free now (Included ASICs: 2,5,6,7,11)
- Skin changed back to white one (too many users complained)
- Improved mode transition between Main/Boot (timeout increased)
- Fixed problem when upon adding “New Path” in “Paths” module Root directory was empty
- CBUS stack improved, if box is disconeected during work, it tries to connect it again instead of “CBUS ERROR”
- Minor changes and bugfixes

How it works?

1. Run Blackberry Module
2. Install drivers (skip this if done already)
3. Click “Read Phone”
4. Connect phone to computer
5. Unlock using calculated codes

Here is example BB8310 Unlocked by Cyclone:
Waiting for new Blackberry USB Device (timeout 30 seconds)…
New device attached, checking if it’s Blackberry…
Blackberry Found!
PIN: 208B60F9
Opened Channel “RIM CalTask”, Proceeding…
IMEI: 358516020462712
HWV-16835-001-1
ASY-15714-005
MEP-06424-002
VSM-17713-001
CFG-10695-065
SFI-15771-033
APP-21301-001
Calculating Codes using Fetched Data…
Handling device: [Cyclone Team], [Cyclone Box]
Service Tag: 6F1079DB8ADD083018BB1FB147B8DEE6
Cyclone Server (1.0.0.598), Cyclone Box Team 2008, 2009, 2010 – Ready.

Please wait…
Codes received: 1
MEP-2 Code: 4910403860764705
All Done!

Where to download?
http://rapidshare.com/files/384772766/Cyclone.exe

Please do not forget also to install Blackberry drivers! You can download latest drivers from here:
http://rapidshare.com/files/384631084/BlackBerry_USB_and_Modem_Drivers_ENG__DM5.0.1b73_.msi

CycloneboxCyclone fixed Installer v1.06 (DCT4)

INSTALLER v1.06
(fixed DCT4 and some other critical bugs)
DOWNLOAD LINK 1
DOWNLOAD LINK 2

CycloneboxCyclone MAJOR Update – New FBUS Protocol (X3,X6) – DCT4RSA(1661,5030) – COM Emulator

Installer v1.05
- Added support for NEW Nokia BB5 FBUS CMT Loaders (flashing new phones – E52 ST Chip, X3, X6, 5530, etc, etc), supported RAPU,RAPIDO,RAPv4 phones,etc. You can flash your phone using New Protocol, but also manage Reading/Writing Certificates,etc.
- Added support for BB5 FBUS New Protocol APE Loaders
- Added support for Unlock / Relock / Autolock DCT4 RSA Based phones (1661, 5030, 1202, and generally ALL ASIC 11 phones), without patch. Solution is standalone and to unlock one phone takes no longer than 2 seconds.
- Added CS Repair due to Bad Simlock in ASIC11 phones (no patch)
- Latest Nokia Loaders 2010 Introduced (including upgraded RAPv3 old prot algo 9.50)
- Added SD Repair, RPL Calc, etc for RAP3v2 phones (hash E9EFF4BFAA5393217CA6B17755FC3E14)
- Added SIMLOCK BACKUP for SL3 phones (can be restored even after fullerase)
- Added support for NCK Reading, SD Extracting, and more accurate Securtity Analysis for v30.xx phones (N96,5800,etc – so called by “mx” team “sl3″ but in fact is simple sl2), previous versions gave msg about “Decryption fails”
- Added COM Emulator – now Cyclone Box can work as UNI BOX with UFS Pinout !
- Added one-click analyze / repair of Dynamic Camera Configuration (blank screen, “camera not ready”,etc) based phones (DCT4plus, 5310, 7210, 5220, 6700, others) supported Camera Drivers:

GR0103D101260C206C02
GR0103D101260C213402
GR0103D10126095A1F05
GR0103D10126095A1F07
GR0103D10126095A1F87
GR0103D1012601022C00
GR0103D1012601022E05
GR09733814140C206C02
GR0973381414095A1F05
GR0973381414095A1F07
GR0973381414095A1F87
GR097338141401022C00
ISL2TI020000093E2F30
NI00IIIIRR030C20C607
NI00IIIIRR03095B1F00
NI00IIIIRR03095B1F01
NI00IIIIRR030102F200
NI00IIIIRR030102F201
NI00IIIIRR030102F202
NI00IIIIRR030102F203
NI00IIIIRR0301035420
NIMMIIIIRRFF0A021001
NIMMIIIIRRFF094B2F01
NIMMIIIIRRFF06150018
NIMMIIIIRRFF06150110
ST090404003C06150018
ST090404004C06150018

- Added TX2 warning when certificate is being not accepted (common problem while writing RPL)
- Updated Nokia USB Connectivity Drivers to 7.1.22.0
- Upon installation, StoredFiles permission is now set to full to avoid Permission problems (and software is still safe for trojans/etc)
- Folder “StoredFiles” is no longer marked to Delete upon Uninstallation to keep old backup files
- Rewritten BB5 RPL Backup routine, now Certificates are being backed-up first, so even if phone is DEAD, still certs will be backed-up
- Factory defaults after flash are now defaultly ticket (BB5,DCT4)
- Mode transition manager added in firmware v01.37
- Software accept Mode Transision to “Normal” when phone goes to “Power Off”
- Flash Variants are displayed now in descending order
- SL Array readen now upon RPL Backup is Keyb/FBUS Count masked
- Now, all 7 codes are being sent to phone (some phones don’t accept +7 codes – tested on N71)
- Fixed NCK Calculation for some mobiles (Security Section Checksum Error)
- When software detects HWC/CCC/Variant certs mismatch, it tries to write local one from database
- Fixed smartcard not responding for reset in some configurations
- Fixed “Failed to Read SP Info” on older RAPv2 phones
- Path manager – bug “/” fixed
- Fixed problems with StoredFiles managing when software have no enough permissions (occurs on WinVista / Win7)
- SX4 Bypass is removed now (no need anymore)
- Improved sending CMT Secondary Loader
- Fixed TX2 test crash when phone is completly erased (TOC erased)
- Added automatic PM upload with field 1,309 after SX4 Authorization (one-click ST_SECURITY_FIX !), Supported 100+ BB5 phones in local database
- Improved Security Analysis, added HWC/CCC/Variant Certs Check
- Box Firmware : 01.0C, Access Violation Fixed
- Runtime Error when “Disable Skins” enabled fixed
- Taksbar problems fixed
- Fixed 1208 UEM Read/IMEI Rebuild
- N73 booting improved (when backing up crt, writing rpl incorrect loaders was assumed before)
- New Nokia Firmware introduced, improved stability a lot
- DCT4Plus relock fixed
- Mode transition improved
- BB5 USB Flashing fixed
- Factory Set problems fixed
- Fixed problems when dealing with RAP3v2 Phones
- Skin manager upgraded to v6.63
- HW Platform is now being readen upon Box Initialization
- Added support for CTF’2010 Platform
- Flashbus writing speed increased about 10%
- Flashbus FUR messages reading speed increased about 40%
- BB5 Booting procedure rewritten, now no problems in phones like 5800,N97,5200,etc..
- After flashing, added average writing speed display
- BootAgent removed, now Bootloader upgrade is managed by middle-loader
- Main Firmware rewritten from scratch, old bugs gone away.
- MPU Added
- Improved Oscillator startup time, box hangup fixed in some cases
- Realtime clock not used anymore, too much hardware problems when box not started
- Fixed booting dead BB5 mobiles
- If bb5 booting fails, SW displays possible reason reported by new firmware
- BB5 is being try to boot now without hardware VCC switch
- Added USB Dualport transactions (increases speed)
- Added old protocols support (tick “Use Old Protocols Loader”)
- Upon finding CMT/APE loaders, it shows a find parameters (TX2 line, Requested Protocol Type, etc)
- BB5 flash_block_Data checksum fixed
- Additional flash chip information is now shown upon BB5 Alg Boot (VPP Info, Chip Size)
- Fixed boot when after activating DCT4 FTD phone comes to dead
- Fixed “Failed to decode MSID” when flashing some PPM DCT4 files
- UPP ID is now represented as hex upon Read Info
- Added detection whether Pri/Sec camera exists or is configurable
- Minor changes and bugfixes
- Black Skin introduced
- Fixed DCT4 Unlock not being executed after Flashing Procedure
- Versions snap
Installer v1.05
Main x86 Application v1.0.0.9392
x86 Memory Manager v4.92
Native USB Drivers v1.0.0.4
USB-COM Stack Drivers v1.0.0.0
Onboard Secure Bootloader v2.10
Onboard Main Nokia Application v01.37
Onboard COM Emulation Code v1.00
Onboard Security Card Revision v1.09
Nokia Connectivity Cable Drivers v7.1.22.0
BB5 USB/FPIF Single Line/FPIF DualLine v20100410
DCT4 FPIF Single Line/USB v20100410
DCT4 Unlock Patches DEPRECATED
Communication Stack SSLv3-keys-06092008
Skin Stack v6.63

Download:
http://rapidshare.com/files/379014856/CycloneBoxInstaller.exe

CycloneboxCyclone Box Firmware v01.36 Released

- Fixed smartcard issues in some enivronments (Smartcard is not responding for reset)
- Fixed issues when some phones couldn’t calculate NCK Codes with new method (Security Section Checksum Error)
- Minor changes and bugfixes
http://www.cyclonebox.com

CycloneboxCycloneBox – DCT4+ Unlock including RSA protected phones

You can download latest beta from here:
http://rapidshare.com/files/376617367/CycloneBeta_DCT4RSA_BB5NewProt.rar

all DCT4+ phones are supported including 1661 , 1662 , 1208, 5030 etc
(please use it only for test DCT4 RSA purposes, full stable installer will be released tonight or tomorrow with some other great and unique features.).
Don’t forget to upgrade box firmware!

CycloneboxCyclonebox – Standalone – SX4 Emulation, SD Repair, RPL Calc, BB5 NCK Calc, more

New version of Cyclone Box Software is ready. There is a lot of changes, here is some of them:

- WORLD’S UNIQUE : Standalone Superdongle Key Calculator Added! No internet, no logs, no time! Calculation time – 0.003 sec ! Works for any SL1, SL2 and SL3.

- WORLD’S UNIQUE : Standalone Unlocking/Relocking using RPL Added! No internet, no logs, no time! Calculation time – 0.002 sec ! Works for any SL1 and SL2.

- WORLD’S UNIQUE : Standalone SX4 Authorization Added! Box is now emulating Nokia SX4 card – no need internet, no need logs to authorize ANY Nokia Phone, just box! Works for any SL1, SL2 or SL3. Emulated SX4 works with ORIGINAL NOKIA Superdongle keys (no need rebuild SD), Custom keys (made by Cyclone,MT,UB), etc. In case of Authorization fail, it will automaticly write and authorize using Custom Keys. Authoirzation time – 0.004 sec ! Supported are RAP and RAPIDO mcu, in case of RAPU phones SX4 Remote Card will be used. After authorization with Cyclone, PHONE STILL CAN be Authorized with ORIGINAL SX4 Card!

- WORLD’S UNIQUE – Cyclone can now authorize Barred Phones (with Correct superdongle keys, but with higher KeyIndex ever used than 0 (possible KeyIndex 0..7), SX4 card can use any higher keyindex at time, when higher key is used, lower keys are automaticly not used in future, and phone requires to use higher key index) – UB and other custom boxes can’t do it as long SX4 emulation is not 100% Nokia-Like

- WORLD’S UNIQUE : Starting from now, Cyclone Box have ability to make _FULL RPL BACKUP_ of BB5 phones! Current existing SW on market creating only some part of RPL (NPC,HWC,Simlock) – Cyclone is now backing up missing part:
- Added SUPER DONGLE KEY extracting (this Original Nokia one, so after writing it back phone still can be authorized with original SX4 card)

- Added CMLA KEY DATA extracting (That means created RPL File by Cyclone is now 100% SAME AS NOKIA’S ONE! )

- WORLD’S UNIQUE : Added BB5 MCU & DSP Timestamps Reader / Diagnostic Tool. This will help diagnostic of downgraded phone, will read Security Block, decode timestamps of current installed SW (and factory one, or Dejan Hack if exists) with FLASH installed MCU/DSP timestamps. Will have ability to FULL REBUILD downgrade security zone (dead06) soon.

- WORLD’S UNIQUE : BB5 Security Block Analyzer added, this will read Security Block and analyze it’s health for content of following Security Data: SIMLOCK DATA, SUPERDONGLE KEY DATA, ECC KEYS DATA, DIV DATA, CMLA (DRM) DATA. Also it reads ST_SIMLOCK_TEST and ST_SECURITY_TEST and when problems occur, recommends actions.

- WORLD’S UNIQUE : Standalone BB5 Calculator Added. This calculated BB5 NCK (levels 1-7) for unlocking purposes. Calculated codes works only with phones which have been relocked with Cyclone Box. To calculate code is needed only IMEI – no need cable, phone, flashbus logger, etc.

- WORLD’S UNIQUE : BB5 Unlock by NCk/RPL, SD Recalc, SX4 auth using USB !! (once log file readen)

- Upon box upgrade (maintenance) Bootloader in box is syncronized with server to avoid Activation Problems
- Bootagent server upgraded to 1.01, fixed “Box is not activated, ID 09)
- Fixed “Access Violation” when Cyclone Box SW is already launched and connection to box opened
- After BB5 Relock, unlock codes is displayed
- More detailed messages is now shown upon new NCK or RPL calculation
- BB5 Security Code Reading is moved to “UserArea” tab (needed space for MCU/DSP timestamp reading and security block analyzing)
- Total unlock/relock time added after operation is finished (thx to arash)
- Box Firmware version is now checked upon loading of Nokia Module – if box firmware is obsolete, SW asks for upgrade and doing it automaticly
- Selected unlock method is now displayed before RootkeyHash support check
- Upon first reading of NCK Code (Extracting) or RPL Calculation, “CYC” log file is stored in “StoredFiles” and next time upon BB5 Security Actions (Calculation of SD, Extracting NCK, Calculating RPL (Relocking)) phone is no booted anymore and whole process took only 1 second!! Keep in mind calculated CYC file is paired with Box Serial number, so in case if your box serial number is changed-go to stored files and purge all “cyc” files.
- Decrypted AES Subblock of Security Block is now checksum checked (16 bytes checksum at end of block)
- Fixed “This is invalid integer…” when parsing phone with damaged IMEI
- When another copy of Cyclone Software is running, message is displayed instead of errors
- New method of NCK Calculation is now default BB5 unlocking method
- When New Method of NCK calculation is selected, PA_SL is not determined already (saves lots of time)
- Skin Manager updated to v6.54 (more stability)
- When BB5 RPL Don’t contain Certificates (NPC,HWC) phone isn’t booted
- Fixed bug when Flash RPL BB5 Data is being written two times
- Added more verbose debug messages when preparing Boot BB5 Phone
- Garbage characters when dealing with SLPA phones (#pw+___garbage___+1) bug fixed
- New splash screen added, thx to arash, again
- When Cyclone fails to boot APE subsystem, it shows hint about TX2
- APE subsystem is now no longer booted upon CheckFlashingBus
- Changed “Failed to write CMT Cert Data (3)” message, added TX2 information
- BB5 TX2 Line test added after “CheckFlashingBus”
- Before RPL Write, Software testing TX2 Line and when its faulty (not adapter) it showing apporiate message
- Writing BB5 CMT HWC Certificate from RPL fixed (thx to arash)
- Parsing some Simlock Arrays (5130) produced garbage output – fixed (thx to arash again)
- Added support for Cyclone Box HW Rev A11D
Just download EXE file and replace at C:\Program files\Cyclone Box\
Make sure Installer is installed aswell (this one from january, else you will have message RootkeyHash not supported).

You don’t need any activations,logs to use this update.

Notes:

SX4 Emulation works offline and emulates SX4 card 1:1, in case of failure still server will be used.

BB5 NCK Calculator works for phone relocked by Cyclone Only (unlocking using IMEI only, no need know other data, just imei – no need cable or connection to box too).

BB5 USB Unlocking and other security tools works only if phone log (by flashbus) is readen before.
Update is fast and most of security functions (sd,rpl) works very fast.

Don’t forget to upgrade your Box Firmware to v01.21.

Download Link : http://rapidshare.com/files/349693053/Cyclone.exe

CycloneboxCyclonebox – First STANDALONE BB5 NCK Calculator Released

- Added STANDALONE, FREE (NO LOGS, NO INTERNET!!!) NCK Reader (levels.. pw1..7) for ALL BB5 RAPv3 and RAPIDO phones (including 9ddb new hash, together PA_SL1 and PA_SL2 phones)
- Unlocking Method is now being selected before unlock
- Added BB5 RPL Calc for PA_SL1 phones (using server) for Simlock Repair
- Few changes with BB5 booting, minor bugfixes, cosmetic changes, etc

FIRMWARE UPGRADE IS MANDATORY IN ORDER TO USE THIS UPGRADE

KEEP IN MIND STILL SOME PHONES (I.E. TELCELL MEXICO) CAN’T BE UNLOCKED USING NCK, THIS CASE USE FREE RPLS.

Avaiable Unlock Methods Now:
PM308 Recalculation (Standalone, Free)
NCK Calculation (Standalone, Free, New Method)
NCK Calculation (Standalone, Free, Old Method) Remark: Works only on SL2 Rapido Phones, SW < v30
RPL Calculation (Server Based, Need Credits)
(need select needed unlock method before unlock)

Download Link : http://rapidshare.com/files/340620565/Cyclone.exe
(REPLACE EXE at C:\Program Files\Cyclone Box\)